SHIPPING TO THE US? No duties and no taxes!

SHIPPING TO THE US? No duties or charges upon delivery!

Contact us for expert assistance.

Your cart

Your cart is empty

Cellar Size (assuming proper insulation - no glass) 2000 cubic feet

BTU/h (85° F condenser air intake temperature)

5254


Dimensions (Evaporator, Ceiling Mounted Inside Cellar):  35.75"L x 14.5"W x 12.75" H
Dimensions (Condenser, Unit Outside Cellar):
110V Unit = 16.06”L x 16.23”W x 12.61”H, 220V Unit = 31.18"L x 10.75"W x 21.18"H
Refrigerant:
R-134a
HP:
110V Unit = 2.06, 220V Unit = 0.7
Voltage Rating:
110V Unit = 115V (15 amp dedicated circuit required), 220V Unit = 220V (15 amp dedicated circuit required)
Weight:
80lbs (evaporator), 66lbs (110V condenser), 56lbs (220V condenser)
Amps:
Evaporator: 1 (running amps), Condenser: 110V Unit = LRA 43/RLA 8, 220V Unit = LRA 13.2A, RLA 3.19A, FLA 3.66A
Drain Line:
1/4” ID clear plastic tubing (not provided - rigid tube recommended)
Ducting:
This is not a ductable unit

View Installation Manual for 110V Units

View Installation Manual for 220V Units

View Installation Manual for Units with 24V Conversion Kit

Addendum to Owners Manual for Systems Purchased After 2/3/20